James Luck (LLi)
banner
jamesmluck.bsky.social
James Luck (LLi)
@jamesmluck.bsky.social
A Equipment tech,
Mostly pertaining to PPE, personnel safety, environmental safety, and interdiction.
Especially pertaining to the detection, characterization, and study of ionizing radiation.

I'm the owner and founder of LLi, Luck Labs Instrumentation.
Neat little source I got to hold.
A vintage Tc99 source, and thanks to Tc99's very long half life, this guy is essentially new still.

With a starting point of 0.224uCi it's now not far off with a estimated 0.2239uCi left.
This guy has a mylar window, and is a purely beta decay.

#hobbynuke
June 29, 2025 at 8:37 AM
New toy is running, just needed some power supply work.
This guy originally was designed for 8 yes eight D sized batteries.
So I put a internal gel cell, since it needs a 12v activation voltage (pulling one out of eberlines playbook huh?), and a 120v socket.
#hobbynuke
June 29, 2025 at 8:28 AM
Amazon battery packs fit, just a little modifying on the belt sander.
Wire loop is to help in removal of pack from meter.

#hobbynuke #Ludlum
April 29, 2025 at 2:53 AM
After a long pinout the 9DP lives.
I did not want to spend $130 on a battery pack, so made my own 🤷‍♂️.
#hobbynuke
April 27, 2025 at 6:24 AM
Welp they look good, and get the job done.
Centering trays for my efficiency sources on my sample counters.
~Ludlum is Alpha, Eberline became a Beta counter.

On a side note I highly doubt I'll make them out of acrylic, that sucked.
#hobbynuke #eberline #Ludlum
March 22, 2025 at 3:23 AM
Now kids dont take candy from strangers,
But what if it comes from a cool science company based out of the states?

#hobbynuke
February 19, 2025 at 6:26 AM
Working on a project doing Air sampling.
Here is the Det portion of a old Eberline SAC-4. The alpha counter uses a 12mm acrylic light guide. This will be replaced with a 10mm Pvt scintillator and a 2mm window assembly for Beta/gamma detection.
Whole assembly will be sheilded by 5mm of lead within.
February 18, 2025 at 1:51 PM
I'm in this Ludlum M9 ionization chamber for desiccant change out, this gives me a great opportunity to show you the chamber itself.
Ludlum uses completely machine PMMA chamber coated in colloidal graphite (Aquadag).
#radiation #hobbynuke
February 9, 2025 at 4:08 AM
If you yavent heard of this I do not fault you.
This is a Ludlum Measurements model 182 Radon Flask probe.

A fancy name for a dark box with a 5in pmt.
I use it for crystal testing.

#radiation #scintillation #hobbynuke
February 7, 2025 at 8:24 PM
Crude but I think this evenings project should be fine until I decide to make a aluminum cap.

Currently the cap is turned pvc, my metal lathe is too greasy to keep any white plastic clean.
#radiation #nuclear #hobbynuke
February 6, 2025 at 5:28 AM
What about full sized probes?
great meter combo.
The FH40G-L10 & a FHZ672 E-10 probe.

A great digital survey meter using a internal gas proportional detector, pared with a large 750mL scintillator capable of H*10 background measurements.

#radiation #nuclear #hobbynuke
February 6, 2025 at 4:20 AM
@melting9.bsky.social Asked if anyone liked full sized survey meters.
Welp, what about full sized probes?
#hobbynuke
February 6, 2025 at 4:06 AM
Nobody likes full sized meters 🤣
February 6, 2025 at 3:44 AM